Troubleshooting

Problem

Possible cause

Solution

The lever handle does not return to its original position.

The handle set is not correctly positioned.

The handle spindle is not accurately positioned.

The product is defective.

The key cannot be pulled out.

The cylinder lock is defective.

The door is stiff when locking and releasing.

The latch and the deadbolt of the main lock do not run smoothly into the striker plate or into the locking rail.

The hook bolt and bolt of the auxiliary box do not run smoothly into the striker plate or into the locking rail.

The routed pockets do not correspond with the specified dimensions.

The product is defective.

The door does not lock automatically.

The multi-point lock is in day mode.

The supply voltage to the multi-point lock is interrupted.

The magnetic sensor is defective.

The position of the drive is not calibrated.

The drive is defective.

The multi-point lock is defective.

The door does not unlock automatically.

The supply voltage to the multi-point lock is interrupted.

The auto-coupling with the connected SI-BUS devices has not functioned.

The magnetic sensor is not working.

The position of the drive is not calibrated.

With connected SIEGENIA access control system:
the pulse control is deactivated in the SIEGENIA app.

With connected SIEGENIA access control system:
the pulse duration in the app is set too long (t> 1s).

The drive is defective.

The multi-point lock is defective.

The drive does not couple itself automatically with the connected SI-BUS devices.

The drive is not set to factory settings.

The software of the drive is not updated.

The connected SI-BUS devices are not set to factory settings.

The software of the connected SI-BUS devices is not updated.

An audible signal is emitted in case of automatic locking.

The wrong cylinder lock is installed.

The cylinder lock is defective.

The magnetic sensor is not working.

The supply voltage or the operating voltage is defective.

The locking elements do not extend.

An audible signal is emitted in case of automatic release.

The wrong cylinder lock is installed.

The cylinder lock is defective.

The locking elements do not retract.

The supply voltage is defective.

The operating voltage is exceeded.

There is an error in the control unit.

The wrong cylinder lock is installed.

The cylinder lock is defective.

The locking elements do not retract.

The multi-point lock does not work.

The connecting clamp is not correctly plugged into the drive bushing.

The magnetic sensor is not working.

The locking elements are extended when the door is open.