Changeover day / night operation
The day-night switchover is the changeover between day mode and night mode.
Daytime mode | Use for highly frequently used doors In case of closed door: no automatic locking. |
Night mode | Use for frequently used doors, e.g. in apartment buildings or private houses When a door is closed: There is automatic locking. |
The day-night changeover can be operated either manually via the LED button or automatically. Connection of a clock timer to terminals 0 and 1 is required for the automatic changeover.
The automatic changeover is only available for the types EB or CB.
The mode of operation is individually adjustable. The following adjustment options are available:
Function | Menu LED button | Connection to terminal 1 | Additional function |
|---|---|---|---|
1 | Inactive | Inactive | – |
2 | Inactive | Active | – |
3 | Active | Inactive | – |
4 | Active | Active | – |
5 | Active | Active | Single switchover between Day and Night mode is possible |
6 | Active | Active | Single switchover from night mode to day mode and back to night mode again is possible |