Digital connection via SI-Bus

Wiring diagram

1

Multi-point lock with electromechanical drive

2

Frame-integrated power supply

3

Cable transfer with integrated SI-BUS plug connection

4

Adapter cable (4-pole PTR plug and SI-BUS plug)

5

Extension cable (SI-BUS plug and power supply connection)

Wiring diagram with 2 ACS and IO module

1

Multi-point lock with electromechanical drive

2

Frame-integrated power supply

3

Cable transfer with integrated SI-BUS plug connection

4

Adapter cable (4-pole PTR plug and SI-BUS plug)

5

Connection cable (bilateral SI-BUS plug)

6

SIEGENIA access control system

7

Adapter cable (6-pole PTR plug and SI-BUS bushing)

8

Connection cable (bilateral SI-BUS plug)

9

Connection cable (bilateral SI-BUS plug)

10

IO module

Terminal allocation, type EA and CA

Drive

Cable

Terminal

Function

Colour (band colour)

Identification

A

SI-BUS

Yellow

0

B

SI-BUS

Green

1

C

- GND

brown

-

D

+ 24 V DC

white

+

0

Not allocated

-

-

1

Not allocated

-

-

2

+ 24 V DC

White (red)

+

3

- GND

Brown (blue)

-

4

Input

Green (yellow)

4

7

Not allocated

-

-

-

-

Blue (white)

Terminal allocation, type EB and CB

Drive

Cable

Terminal

Function

Colour (band colour)

Identification

A

SI-BUS

Yellow

0

B

SI-BUS

Green

1

C

- GND

brown

-

D

+ 24 V DC

white

+

0

Input

Grey (black)

0

1

Input

Yellow (brown)

1

2

+ 24 V DC

White (red)

+

3

- GND

Brown (blue)

-

4

Input

Green (yellow)

4

7

Output

Pink (violet)

7

-

-

Blue (white)