Mounting sensor and plug-in cam
Use the sensor and the plug-in cam for window sashes with oblong holes and without cams (1) and for surface-mounted striker plates (2).
- Open the window.
- Clean the window sash at the installation position. The installation position must be dry, dust-free and grease-free.
- Remove the magnet from the slider.
- Fix the magnet to the plug-in cam.
- Clip the plug-in cam into the window hardware.
NOTICE
Material damage due to incorrect adhesion
The sensor can fall off and shatter due to incorrect adhesion.
- Clean the installation position so that it is dry and free of dust and grease.
- Only use the adhesive pads 1x.
- If the adhesive pads have already been used, then use adhesive tape VHB 5925 F from the producer 3M.
- To glue the sensor adhesive pad correctly: for left-hand opening windows, fix the sensor so that the marking "L" is visible. For right-hand opening windows, fix the sensor so that the marking "R" is visible.
- Glue the sensor adhesive pad to the sensor and press for at least 5 seconds.
- Position the sensor on the window sash (1). The marking on the sensor must be flush with the magnet (2). Press the sensor to the window sash for at least 5 seconds.