Adjustment of status query for the status feedback
Menu level 1 | Menu level 2 |
---|---|
Menu level 1 | Menu level 2 | value | |
---|---|---|---|
Status request | |||
A | The door is closed and locked. (default setting) | ||
B | In day mode: the door is closed. In night mode: the door is closed and locked. | ||
C | The latch is retracted. | ||
D | Active error The latch is retracted. The multi-point lock is in the locking process or in the unlocking process. The door is closed and locked. The door is closed and not locked. | ||
E | The door is released. | ||
F | No active error |
Prerequisites
- The status LED lights up green.
- The LED button lights up white in day mode or blue in night mode.
- Press the LED button if no LEDs light up.
- To change to menu level 1, press and hold down the LED button for 8 seconds until it light up magenta and emits an acoustic signal.
- To adjust the status query for status feedback, press the LED button 1x until it lights up yellow.
- To change to menu level 2, press and hold down the LED button for 3 seconds.
- In the menu level 2 the adjusted value flashes first.
- To select the desired status query, press the LED button according to the scheme.
- Hold down the LED button for 3 seconds to save the selected status query.