Intended use
GENIUS 2.2 and 2.3 are door locks that lock and release entrance doors electromechanically.
- The product is suitable for installation in entrance doors made of timber, metal or PVC.
- The product is suitable for installation in 1-sash and 2-sash doors in permanent buildings.
- The products are suitable for use in vertically installed doors.
- Do not use the product in rescue routes in accordance with DIN EN 179.2008 or DIN EN 1125.2008.
- Modifications of the product for use in fire-rated doors, which are not defined in these instructions, are inadmissible.
- Only use the product in conjunction with the approved fire protection cable in fire-rated doors.
- Only use the product in conjunction with the approved emergency power buffer or with the authorised USV in fire-rated doors or fire protection doors.
- An electrical or mechanical snib latch is inadmissible in fire-rated doors.
- The product for automatic door release with the SIEGENIA access control system is inadmissible in fire-rated doors.
- Only use accessories that are tested and certified in accordance with the EMC directive. Any change of this combination (even a partial change) or any change of the product is inadmissible.
- Only use cylinder locks with free-running cam FZG in accordance with DIN 18252.
- If the product is installed in combination with a motorised door drive, the motorised door drive must be tested according to EN 16005.
- Do not route SI-BUS cables and analogue cables on cable racks, in roof cavities or in shared cable ducts in public buildings or high-rise buildings.